Conpot methodology & trust notes

Status: Informative · evaluation proof
Related: TUTORIAL.md · full/run-meta.json · quick/run-meta.json


1. Claims / non-claims

We claim We do not claim
Artifacts come from UHBS-Lab v4.0.1 against a live Conpot container Modbus :5020 That Conpot is UHBS-certified
Full run used 1000-sample timing, source audit, SAST, and real log directory That Module A exercised every Modbus function code / every Conpot template
Manifests include SHA-256 digests That Docker Desktop equals a production air-gap
Grades follow normative UHQS / δ_C math That UHBS is an industry consortium standard
Module D skipped shell probes because this decoy has no SSH listener (correct for Modbus-primary ICS) That other Conpot listeners (HTTP/S7/SNMP/…) were graded

2. Software under test

Field Value
Project mushorg/conpot
Description ICS/SCADA honeypot (default multi-protocol template)
Git commit b82b7a7fae8866c648f7be37f7033481a1b93482
Image conpot:lab-fixed (upstream build + setuptools<81 wrapper)
Image id sha256:a59010a7d6b449906612343cb36e762e4d0f6f2cd1d3e7e0174381d9926f4abe
Graded listen TCP 5020 Modbus (host publish 502:5020)
Template note Default Modbus mode=serial, delay=100; slaves expose coils/discrete/analog — not holding registers at addr 0

3. Grader

Field Full Quick
Image uhbs:4.0.1-full uhbs:4.0.1
TPS labs/conpot/ics_modbus_full.yaml labs/conpot/ics_modbus_quick.yaml
Inventory labs/conpot/inventory.yaml CLI + quick TPS
Protocol plugin modbus same
Profile class ICS-SCADA same
Module E concurrency 5, requests 50 UHBS_QUICK caps

Why ICS-SCADA? Matches the industrial decoy class weights (heavy Module A).
Why Modbus-only? UHBS has a first-class Modbus plugin; grading every Conpot listener in one UHQS would mix protocols and obscure failure modes.


4. Topology

┌──────────────────────┐   network uhbs-lab    ┌──────────────────────────┐
│ uhbs:4.0.1[-full]    │ ───────────────────── │ conpot-lab               │
│ mounts /honeypot     │ ← source tree         │ Modbus :5020 (graded)    │
│ mounts /telemetry    │ ← conpot.log          │ (+ other listeners N/A)  │
└──────────────────────┘                       └──────────────────────────┘

5. Module notes (full)

Module What ran Outcome driver
A Modbus FSM + FC03 nego + 1000× timing FC03 illegal data address on default map → nego 30; timing strong
B FC06 write/read + binary fuzz Survives blast; write/read exchange completed
C /telemetry with conpot.log Text logs → no STIX/OTel → capped at 55
D No shell-exec port Airgap + clean gateway → C=90, δ_C=0.81
E 5×50 connect load P95 ~1.7 ms; moderated vs 25×200 (Conpot CLOSE_WAIT fragility)
F bandit + semgrep on source Template SSL keys + Bandit HIGH → F capped at 70

6. Integrity

python - <<'PY'
import hashlib, json
from pathlib import Path
for mode in ("quick", "full"):
    root = Path(f"docs/conformance/reports/conpot/{mode}")
    man = json.loads((root / "MANIFEST.json").read_text())
    print("==", mode, "==")
    for art in man["artifacts"]:
        p = root / art["path"]
        h = hashlib.sha256(p.read_bytes()).hexdigest() if p.is_file() else None
        print(("OK" if h == art["sha256"] else "FAIL"), art["path"])
PY

uhbs validate-scorecard docs/conformance/fixtures/conpot-ics-scada.scorecard.json --strict

7. Limitations

  1. Holding-register probe vs default map — Module A FC03 failure is template realism, not “Modbus dead.”
  2. Air-gap attestedUHBS_AIRGAP_ATTESTED=1 inside Docker Desktop.
  3. No remote shell containment probes — Module D only Paramikos an explicit ports.ssh / ssh_port.
  4. Telemetry format — classic text logger, not detection-pipeline schemas.
  5. Moderated Module E — published full run is not a 25×200 storm (that wedged Conpot in this lab).
  6. Other protocols — HTTP/S7/SNMP/BACnet/… not included in UHQS.
  7. Non-endorsement — naming Conpot ≠ UHBS requirement.

8. Replication

Follow TUTORIAL.md. Compare image digests and run-meta.json if UHQS diverges.